Resource Type

Journal Article 722

Conference Videos 41

Conference Topics 1

Year

2024 1

2023 56

2022 89

2021 56

2020 49

2019 49

2018 51

2017 43

2016 40

2015 66

2014 28

2013 41

2012 17

2011 24

2010 27

2009 25

2008 18

2007 22

2006 8

2005 8

open ︾

Keywords

maximum power point tracking (MPPT) 11

wind power 10

manufacturing power 8

renewable energy 8

nuclear power plant 7

optimization 6

power quality 6

automobile power 5

sustainable development 5

Active learning 4

MR damper 4

Reactive oxygen species 4

manufacturing 4

offshore wind power 4

power generation 4

reactive oxygen species 4

smart grid 4

Artificial intelligence 3

control 3

open ︾

Search scope:

排序: Display mode:

Performance of PI controller for control of active and reactive power in DFIG operating in a grid-connected

Azzouz TAMAARAT,Abdelhamid BENAKCHA

Frontiers in Energy 2014, Volume 8, Issue 3,   Pages 371-378 doi: 10.1007/s11708-014-0318-6

Abstract: The objective of this work is to present the modeling and control strategy of a grid connected wind powerIt will introduce the vector control, which makes it possible to control independently the active andreactive power exchanged between the stator of the generator and the grid, based on vector control conceptIt is also interesting to play on the quality of electric power by controlling the reactive power exchangedwith the grid, which will facilitate making a local correction of power factor.

Keywords: wind power     doubly fed induction generator (DFIG)     vector control     active power     reactive power     maximum power    

Active-reactive power scheduling of integrated electricity-gas network with multi-microgrids

Frontiers in Energy 2023, Volume 17, Issue 2,   Pages 251-265 doi: 10.1007/s11708-022-0857-1

Abstract: development of the integrated electricity-gas network (IEGN) and strengthening the interaction between the active-reactiveThis paper proposes a day-ahead active-reactive power scheduling model for the IEGN with multi-microgridsBesides, motivated by the non-negligible impact of the reactive power, optimal inverter dispatch (OID) is considered to optimize the active and reactive power capabilities of the inverters of distributedFurther, a second-order cone (SOC) relaxation technology is utilized to transform the proposed active-reactive

Keywords: combined cooling     heating     and power (CCHP)     integrated energy systems (IES)     natural gas     power distribution    

Rapid transaction to load variations of active filter supplied by PV system

M. BENADJA,S. SAAD,A. BELHAMRA

Frontiers in Energy 2014, Volume 8, Issue 3,   Pages 335-344 doi: 10.1007/s11708-014-0325-7

Abstract: control of a photovoltaic (PV) system connected to the main supply through a Boost converter and shunt activeValidation of the developed model and control strategy is conducted using power system simulator Sim-PowerTo demonstrate the effectiveness of the shunt active filter to load changes, the method of instantaneouspower ( theory) is used to identify harmonic currents.obtained results show an accurate extraction of harmonic currents and perfect compensation of both reactive

Keywords: solar panels     maximum power point tracking (MPPT)     DC/DC converter (Boost)     shunt active filter     instantaneouspower control     power quality     harmonics     imbalances     reactive energy    

A New Real-time Detecting Method for Harmonic Current Based on Iterative Algorithm in Active Power Filter

Li Zicheng,Sun Yukun

Strategic Study of CAE 2006, Volume 8, Issue 1,   Pages 46-50

Abstract:

At present, many detecting methods for harmonic and reactive currents have been put forward.current analysis, a new real-time detecting method for harmonic current based on iterative algorithm in activepower filter is proposed, It has the characteristics of very little calculating work, nice real time

Keywords: active power filter     harmonics current     active current     reactive current    

Robust control based on the Lyapunov theory of a grid-connected doubly fed induction generator

Ridha CHEIKH, Arezki MENACER, Said DRID

Frontiers in Energy 2013, Volume 7, Issue 2,   Pages 191-196 doi: 10.1007/s11708-013-0245-y

Abstract: strategy in order to ameliorate the performances of the control and to govern the developed stator activeand reactive power in a linear and decoupled manner, in which an optimal operation of the DFIG in sub-synchronousoperation is given, as well as the control stator power flow with the possibility of keeping statorpower factor at a unity.

Keywords: doubly fed induction generator (DFIG)     vector control     Lyapunov function     power factor unity     active power     reactive power    

UPFC setting to avoid active power flow loop considering wind power uncertainty

Shenghu LI, Ting WANG

Frontiers in Energy 2023, Volume 17, Issue 1,   Pages 165-175 doi: 10.1007/s11708-020-0686-z

Abstract: The active power loop flow (APLF) may be caused by impropriate network configuration, impropriate parameterThe power flow controllers, e.g., the unified power flow controller (UPFC), may be the reason and theapproaching to the critical existing condition, the integrated power flow needs less iterations andBesides, with wind power fluctuation, the interval power flow (IPF) is introduced into the integratedpower flow, and solved with the affine Krawcyzk iteration to make sure that the range of active power

Keywords: active power loop flow (APLF)     unified power flow controller (UPFC)     wind power uncertainty     interval power    

Application of fuzzy logic control algorithm as stator power controller of a grid-connected doubly-fed

Ridha CHEIKH, Arezki MENACER, Said DRID, Mourad TIAR

Frontiers in Energy 2013, Volume 7, Issue 1,   Pages 49-55 doi: 10.1007/s11708-012-0217-7

Abstract: This paper discusses the power outputs control of a grid-connected doubly-fed induction generator (DFIG) for a wind power generation systems.So, to supply commercially the electrical power to the grid without any problems related to power quality, the active and reactive powers ( , ) at the stator side of the DFIG are strictly controlled at a requiredflow with the possibility of keeping stator power factor at a unity.

Keywords: doubly-fed induction generator (DFIG)     vector control     fuzzy logic controller     optimization     power factorunity     active and reactive power    

Robust direct power control based on the Lyapunov theory of a grid-connected brushless doubly fed induction

M. Abdelbasset MAHBOUB,Said DRID,M. A. SID,Ridha CHEIKH

Frontiers in Energy 2016, Volume 10, Issue 3,   Pages 298-307 doi: 10.1007/s11708-016-0411-0

Abstract: This paper deals with robust direct power control of a grid-connected brushless doubly-fed inductionstrategy, an attempt is made to improve the desired performances by controlling the generated stator activeand reactive power in a linear and decoupled manner.Thus, an optimal operation of the BDFIG in sub-synchronous operation is obtained as well as the stator powerflows with the possibility of keeping stator power factor at a unity.

Keywords: brushless doubly fed induction generator (BDFIG)     vector control     Lyapunov theory     power factor unity     activeand reactive power    

Tuned reactive power dispatch through modified differential evolution technique

S. BISWAS (RAHA), N. CHAKRABORTY

Frontiers in Energy 2012, Volume 6, Issue 2,   Pages 138-147 doi: 10.1007/s11708-012-0188-8

Abstract: This paper explores the capability of modified differential evolution (MDE) technique for solving the reactivepower dispatch (RPD) problem.

Keywords: reactive power dispatch (RPD)     modified differential evolution (MDE)     differential evolution algorithm    

Constriction factor based particle swarm optimization for analyzing tuned reactive power dispatch

Syamasree BISWAS(RAHA), Kamal Krishna MANDAL, Niladri CHAKRABORTY

Frontiers in Energy 2013, Volume 7, Issue 2,   Pages 174-181 doi: 10.1007/s11708-013-0246-x

Abstract: The reactive power dispatch (RPD) problem is a very critical optimization problem of power system whichminimizes the real power loss of the transmission system.In connection with the RPD problem, solving reactive power is compensated by incorporating shunt capacitors

Keywords: real power loss minimization     voltage stability     constriction factor     particle swarm optimization (PSO)    

concentrations of ionic silver promote the proliferation of human keratinocytes by inducing the production of reactive

Xiaodong Duan, Daizhi Peng, Yilan Zhang, Yalan Huang, Xiao Liu, Ruifu Li, Xin Zhou, Jing Liu

Frontiers of Medicine 2018, Volume 12, Issue 3,   Pages 289-300 doi: 10.1007/s11684-017-0550-7

Abstract: /sup>) on the proliferation of human skin keratinocytes (HaCaT) and the production of intracellular reactiveAfter treating HaCaT cells with Ag+and/or the active oxygen scavenger N-acetyl cysteine (NAC

Keywords: ionic silver     human keratinocyte     cell proliferation     reactive oxygen species     active oxygen scavenger     NAC    

THD reduction with reactive power compensation for fuzzy logic DVR based solar PV grid connected system

Akhil GUPTA,Saurabh CHANANA,Tilak THAKUR

Frontiers in Energy 2014, Volume 8, Issue 4,   Pages 464-479 doi: 10.1007/s11708-014-0307-9

Abstract: Power quality improvement with comparison is conducted during fault with proportional integral (PI) andMPPT tracks the actual variable DC link voltage while deriving the maximum power from a photovoltaicresults during fault show that the fuzzy logic based DVR scheme demonstrates simultaneous exchange of activeand reactive power with less total harmonic distortion (THD) present in voltage source converter (VSC) current and grid current with fast tracking of optimum operating point at unity power factor.

Keywords: fuzzy logic     maximum power point tracking (MPPT)     proportional integral (PI)     control     voltage restorer    

Power quality improvement using fuzzy logic controller for five-level shunt active power filter under

Amar BENAISSA,Boualaga RABHI,Ammar MOUSSI

Frontiers in Energy 2014, Volume 8, Issue 2,   Pages 212-220 doi: 10.1007/s11708-013-0284-4

Abstract: In this paper, a five-level inverter is used as a shunt active power filter (APF), taking advantagesIt is used to compensate reactive power and eliminate harmonics drawn from a thyristor rectifier feeding

Keywords: active power filter (APF)     harmonics isolator     distorted voltage conditions     self-tuning filters (STF)     fuzzy    

Robust switched fractional controller for performance improvement of single phase active power filter

H. AFGHOUL,F. KRIM,D. CHIKOUCHE,A. BEDDAR

Frontiers in Energy 2016, Volume 10, Issue 2,   Pages 203-212 doi: 10.1007/s11708-015-0381-7

Abstract: A novel controller is proposed to regulate the DC-link voltage of a single phase active power filterThus, the purpose of this paper is to switch to the PI controller in steady-state to obtain the best power

Keywords: calculus (FC)     total harmonic distortion (THD)     Oustaloup continuous approximation (OCA)     single phase activepower filter (SPAPF)    

An improved delta-star switching scheme for reactive power saving in three-phase induction motors

P. RAJA,N. KUMARESAN,M. SUBBIAH

Frontiers in Energy 2014, Volume 8, Issue 3,   Pages 364-370 doi: 10.1007/s11708-014-0324-8

Abstract: method of choosing a suitable value for the capacitor and the criteria to be adopted for calculating the powerAny further improvement in grid side power factor can be achieved by employing a static synchronous compensator

Keywords: delta-star switching     induction motor     power factor     steady-state analysis    

Title Author Date Type Operation

Performance of PI controller for control of active and reactive power in DFIG operating in a grid-connected

Azzouz TAMAARAT,Abdelhamid BENAKCHA

Journal Article

Active-reactive power scheduling of integrated electricity-gas network with multi-microgrids

Journal Article

Rapid transaction to load variations of active filter supplied by PV system

M. BENADJA,S. SAAD,A. BELHAMRA

Journal Article

A New Real-time Detecting Method for Harmonic Current Based on Iterative Algorithm in Active Power Filter

Li Zicheng,Sun Yukun

Journal Article

Robust control based on the Lyapunov theory of a grid-connected doubly fed induction generator

Ridha CHEIKH, Arezki MENACER, Said DRID

Journal Article

UPFC setting to avoid active power flow loop considering wind power uncertainty

Shenghu LI, Ting WANG

Journal Article

Application of fuzzy logic control algorithm as stator power controller of a grid-connected doubly-fed

Ridha CHEIKH, Arezki MENACER, Said DRID, Mourad TIAR

Journal Article

Robust direct power control based on the Lyapunov theory of a grid-connected brushless doubly fed induction

M. Abdelbasset MAHBOUB,Said DRID,M. A. SID,Ridha CHEIKH

Journal Article

Tuned reactive power dispatch through modified differential evolution technique

S. BISWAS (RAHA), N. CHAKRABORTY

Journal Article

Constriction factor based particle swarm optimization for analyzing tuned reactive power dispatch

Syamasree BISWAS(RAHA), Kamal Krishna MANDAL, Niladri CHAKRABORTY

Journal Article

concentrations of ionic silver promote the proliferation of human keratinocytes by inducing the production of reactive

Xiaodong Duan, Daizhi Peng, Yilan Zhang, Yalan Huang, Xiao Liu, Ruifu Li, Xin Zhou, Jing Liu

Journal Article

THD reduction with reactive power compensation for fuzzy logic DVR based solar PV grid connected system

Akhil GUPTA,Saurabh CHANANA,Tilak THAKUR

Journal Article

Power quality improvement using fuzzy logic controller for five-level shunt active power filter under

Amar BENAISSA,Boualaga RABHI,Ammar MOUSSI

Journal Article

Robust switched fractional controller for performance improvement of single phase active power filter

H. AFGHOUL,F. KRIM,D. CHIKOUCHE,A. BEDDAR

Journal Article

An improved delta-star switching scheme for reactive power saving in three-phase induction motors

P. RAJA,N. KUMARESAN,M. SUBBIAH

Journal Article